Shangu Maglev Turbo Blower

Short Description:
magnetic bearing turbo blower technology from France, 30-50% energy saving than roots blower

Configuration Turbo Blower :

-Core Technology from France

High-efficiency centrifugal impeller

Adopt ternary flow theory design to maximize

impeller efficiency and wide working area

Centrifugal impeller is made of high-strength forged aluminum, which has strong resistance to deformation

Accurately processed by a five-axis CNC machining center
The surface of the impeller is treated with anodized acid, which enhances the corrosion resistance of the impeller and reduces wear

during long-term high-speed operation

High power high speed permanent magnet synchronous motor 

Use High speed and high power permanent magnet synchronous motor

Small motor, light weight and high power density

High motor speed, up to 42,000 rpm

Achieve stepless speed control

Motor rotor and impeller adopt direct connection structure, with low operating failure rate and high transmission efficiency

Five degrees of freedom magnetic bearing

Maglev bearing suspends the rotating shaft stably through controllable electromagnetic suction force, during the rotation process
The shaft has no mechanical contact and mechanical friction, so it is highly efficient.

No speed-increasing gear or oil bearing

No lubricant required
No oil from Discharge

Dedicated control system

High-power inverter speed control system with completely independent intellectual property rights

Inverter measured efficiency (output work/input work) up to 98%

Adjust the motor speed by changing the frequency of the inverter output current to adjust the flow

Wide working range, automatic adjustment of motor speed according to pipe network conditions,achieve accurate aeration

The motor control system, maglev control system and the whole machine control system are integrated.

 

Specification and Parameters

Model SC22 SC30 SC37 SC45 SC55 SC75 SC110 SC150 SC200 SC250 SC300 SC350 SC400
△P(kpa) Flow Rate(m3/min):1ATM,20℃
40 20 32 38 47 60 90 123 180 235
50 17 24 33 40 50 75 103 150 190 240 290 375 390
60 15 21 28 34 40 65 88 130 160 205 245 320 330
70 13 19 25 31 35 55 78 105 145 180 220 280 290
80 10 18 22 28 32 50 73 90 130 155 185 250 255
90 30 45 63 80 115 140 165 225 240
100 58 70 110 130 150 205 220
120 100 115 130 180 190

Performance and Advantages:

  1. High Benefits and Profitability

Driven by Self-designed high-efficiency Centrifugal impeller+high-efficiency permanent magnet synchronous motor

30% more efficient than traditional volumetric Roots blowers

20% more efficient than traditional multi-stage centrifugal blowers

12% more efficient than traditional geared single-stage centrifugal blowers

2.No Lube,No Mechanical Maintenance

Due to the use of advanced magnetic levitation bearing technology, the complicated gearboxes and oily bearings necessary for traditional blowers are eliminated, so no lubricant and no mechanical maintenance are achieved.

Effectively reduce the maintenance cost of users, improve the stability of the operation of the aeration system and the entire sewage treatment plant.

3.Low vibration and low noise

Since use the advanced maglev bearing system, the rotating parts have no contact and no mechanical friction with the mechanical system, which has stable operation, low vibration, and low machine noise.

4.Easy Installation and Maintenance

The maglev centrifugal blower is light in weight and small in size, and does not require large lifting equipment. Installation can be easily done by two technicians.

Regular maintenance only needs to replace the air filter, which is convenient and simple .

 

Installation Dimension and Requirement:

Installation Dimension:

Model Dimension
L W H
SC75 1650 1250 1600
SC100 1700 1400 1700
SC150 1850 1450 1900
SC200 2500 1600 1900
SC300 3000 1700 2200
SC400 3200 2000 2300

Installation Requirement:

Minimum Requirement of the distance from the Roof and the Top=D1

Minimum Requirement of the distance from Back to Side=D2

Minimum Requirement of the distance from Left to Side=D3

Minimum Requirement of the distance from Front to Side=D4

Minimum Requirement of the distance from Right to Side=D5

Sufficient space must be left around the blower to meet the needs of disassembly, assembly and routine maintenance. The space requirements are as follows:

① The distance between the top of the blower skid and the roof should be at least 1.5 m;

② The foundation requirement of the unit is a reinforced concrete leveling foundation with sufficient strength to support the weight of the blower and ensure long-term stability.
Avoid mezzanine, overhead and hollow floors.

③ The clearance on the side (front) of the control cabinet of the sowing body should be at least 1m away;

④ The clearance on the side (back) of the prying frame blower should be at least 1m

⑤The clearance of the air inlet side (left side) of the prying frame should be at least 1m;

⑥ The clearance on the opposite side (right side) of the air inlet of the prying frame should be at least 1m away;

The distance between two adjacent blowers should be at least 1m;

Leave Your Message

RELATED PRODUCTS

Shandong Mingtian Machinery Group Joint Stock Co., Ltd. was established in 2007 and is located in Zhangqiu District, Jinan City, Shandong Province. It is a national high-tech enterprise integrating scientific research, production and sales. The annual output value of the group company is as high as 150 million yuan, covering an area of more than 36,000 square meters, and a building area of more than 19,000 square meters. 